Skip to main content

Table 1 Summary of performed comparison studies between ImmunoCAP and IMMULITE

From: Distinct differences in analytical performance of two commercially available assays for specific IgE to egg white and house dust mite allergens

Comparison of: Assays
IMMULITE
ImmunoCAP
Type of study Type of comparison
Whole extract EW (n = 36) sIgE
HDM (n = 44) sIgE
Correctness by sample dilution linearity Ratio of observed value and expected value (O/E)
Allergen-specific mouse-human chimeric IgE monoclonal antibodies Der p 1, Der p 2
Gal d 1, Gal d 2, Gal d 4
sIgE
Total IgE (ImmunoCAP)
Accuracy by sIgE/tIgE agreement in dilution series Ratio of observed value and total IgE value (sIgE/tIgE)
Mouse monoclonal ab (IgG) addition test with 3 concentrations:   Interference study Ratio of observed value to the control (initial level with no addition of mIgG ab)
Anti-Der p 1 mIgG HDM sIgE   
Anti-Gal d 2 mIgG EW sIgE   
Addition of Der p 2-chimeric IgG4 antibody to 2 sIgE positive patient samples previously tested for house dust mite (13.4 kUA/L and 78.7 kUA/L) HDM sIgE Interference study Ratio of observed value to the control (initial level with no addition of IgG4 ab)